Outpatient Surgery Magazine

Her Loss, Their Gain - October 2019 - Subscribe to Outpatient Surgery Magazine

Outpatient Surgery Magazine, providing current information on Surgical Services, Surgical Facility Administration, Outpatient Surgery News and Trends, OR Excellence and more.

Issue link: http://outpatientsurgery.uberflip.com/i/1174852

Contents of this Issue

Navigation

Page 99 of 126

sine triphosphate (ATP). ATP is an organic chemical that provides energy for many different processes in cells. It's also a substrate for enzymes and is an impor- tant part of RNA synthesis. The presence of ATP, above a certain threshold, is an indicator that potentially pathogenic material still remains in the scope. There are many options available for performing cleaning verifica- tion. Some kits may test for one or more of protein, hemoglobin and carbohydrates. This test is usually performed by flushing sterile water through a channel or swabbing a surface of a scope with a test strip to determine the presence of organic material. ATP kits include collection materials and a bioluminescence reader, which measures the amount of ATP present using relative light units (RLUs). Cleaning verification tests are usually set to read as pass/fail, although some ATP tests report the results in RLUs, which should be clarified for a threshold of pass/fail by the manufacturer. It's important to note that after manual cleaning and before high-level disinfection, there may be some organic material present. The cleaning verification tests determine whether the amount of organic material has been reduced enough to make high-level disinfection effective and render the endoscope safe for patient use. There is a wide variance of cost among the different tests available. Work with your infection preventionist to determine which test, or combination of tests, would be best for your facility; it's important to investigate which form of testing can be done correctly and consis- tently, with results that are easy to interpret. You should also develop policies and procedures for managing scopes that have failed a single cleaning verification test and those that fail multiple tests. These scopes may be damaged and harboring debris that is impossible to remove. They must be cleaned and disinfected, according to the OEM 1 0 0 • O U T PA T I E N T S U R G E R Y M A G A Z I N E • O C T O B E R 2 0 1 9

Articles in this issue

Archives of this issue

view archives of Outpatient Surgery Magazine - Her Loss, Their Gain - October 2019 - Subscribe to Outpatient Surgery Magazine